CH-222
Abyss™ Jr.
USER MANUAL
Chauvet, 3000 N 29th Ct, Hollywood, FL 33020 U.S.A
(800) 762-1084 – (954) 929-1115
FAX (954) 929-5560
2005-07-22/17:40
BEFORE YOU BEGIN
What is included
1 x Abyss™ Jr. (CH-222)
Power cord with plug
EFP5 100w lamp
Warranty Card & Manual
Unpacking Instructions
Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that
all parts are present, and have been received in good condition. Notify the shipper immediately and
retain packing material for inspection if any parts appear damaged from shipping or the carton itself
shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture
must be returned to the factory, it is important that the fixture be returned in the original factory box
and packing.
Power
To determine the power requirements for a particular fixture, see the label affixed to the back plate of
the fixture or refer to the fixture’s specifications chart.
A fixture’s listed current rating is its average current draw under normal conditions.
All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat (variable
resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0% to 100%
switch.
Before applying power to a fixture, check that the source voltage matches the fixture’s requirement.
All fixtures must be connected to circuits with a suitable Earth Ground.
Warning!
Verify that the power requirement on your unit matches the line voltage applied. All
fixtures must be connected to circuits with a suitable Earth Ground.
Safety Instructions
Please read these instructions carefully, which includes important
information about the installation, usage and maintenance?
Please keep this User Guide for future consultation. If you
sell the unit to another user, be sure that they also receive
this instruction booklet.
Secure fixture to fastening device using a safety chain.
Never carry the fixture solely by its head. Use its carrying
handles.
Maximum ambient temperature is Ta: 40°. Do not operate
fixture at temperatures higher than this.
In the event of serious operating problem, stop using the
unit immediately. Never try to repair the unit by yourself.
Repairs carried out by unskilled people can lead to
damage or malfunction. Please contact the nearest
authorized technical assistance center. Always use the
same type spare parts.
Don’t connect the device to a dimmer pack.
Make sure power cord is never crimped or damaged.
Never disconnect power cord by pulling or tugging on the
cord.
Always make sure that you are connecting to the proper
voltage and that the line voltage you are connecting to is
not higher than that stated on decal or rear panel of the
fixture.
This product is intended for indoor use only!
To prevent risk of fire or shock, do not expose fixture to
rain or moisture. Make sure there are no flammable
materials close to the unit while operating.
The unit must be installed in a location with adequate
ventilation, at least 50cm from adjacent surfaces. Be sure
that no ventilation slots are blocked.
Always disconnect from power source before servicing or
replacing lamp or fuse and be sure to replace with same
lamp source.
Avoid direct eye exposure to lamp while it is on.
Caution!
There are no user serviceable parts inside the unit. Do not open the housing or
attempt any repairs yourself. In the unlikely event your unit may require service,
please contact CHAUVET.
CH-222 User Manual
3
2005-07-22/17:40
INTRODUCTION
The Abyss Jr. projects a wave simulation effect on a wall or any flat surface. It is a wonderful scenic
effect that adds life and color to any venue.
Features
water undulation effect (wave effect)
bright EFP5 100w MR-16 lamp
fan cooled
Product Overview
Hanging
Bracket
Lamp access
Power
connector
Figure 1 Product Overview
CH-222 User Manual
4
2005-07-22/17:40
SETUP
Lamp
You will need to install a lamp prior to the initial operation of the fixture. An EFP 100W halogen lamp
is included.
Warning!
When replacing the lamp, please wait 15 minutes after powering down to allow the
unit to cool down! Always disconnect from main power prior to lamp replacement.
Do not touch the envelope (glass area) of the bulb with
Figure 2 – CH-222 Lamp installation
bare hands. If this happens, clean the lamp with alcohol
and wipe it with a lint free cloth before installation.
LAMP INSTALLATION
1) Remove the four screws located on both sides of
the fixture and remove fixture cover.
2) If replacing the lamp, remove old lamp first.
3) Reach in and slide the lamp out of the retaining
Remove screws on both sides.
cage.
4) Detach the lamp from the lamp socket and
replace.
5) Replace fixture cover, align the screw holes and
fasten the screws.
6) No lamp alignment is necessary for this fixture
since the lamp is already optimized inside the
reflector.
Lamp exposed
Mounting
ORIENTATION
This fixture may be mounted in any position provided there is adequate room for ventilation.
RIGGING
Figure 3 - Hanging Clamp
It is important never to obstruct the fan or vents pathway. Mount the
fixture using, a suitable “C” or “O” type clamp. Adjust the angle of the
fixture by loosening both knobs and tilting the fixture. After finding the
desired position, retighten both knobs.
When selecting installation location, take into consideration lamp
replacement access and routine maintenance.
Safety cables should always be used.
Never mount in places where the fixture will be exposed to rain, high humidity, extreme temperature
changes or restricted ventilation.
Note!
Clamps sold separately!
CH-222 User Manual
5
2005-07-22/17:40
OPERATING INSTRUCTIONS
The Abyss Jr. is a water ripple or undulation simulation effect that requires no additional connections
or a controller to operate. It is especially functional when used to project on a light colored surface,
preferably a pastel or white.
Whether used in a mobile or permanent environment, you may find it useful to control this effect by
means of a relay system for remote switching or to go with DMX control, use the latest in DMX
compatible (Dimmer Relay Pack), all available from CHAUVET.
A relay system will allow you to remotely trigger the Abyss™ Jr. and any other non-dimmable effect
light from a switch panel. Make sure to use a cable of at least 25 feet to provide ample distance
between the control panel and the switch pack for most mobile lighting applications.
If you would prefer to control it directly from your DMX lighting console then we suggest a DMX
compatible (relay switch-pack). These devices are an extremely affordable solution to operating non-
DMX lighting effects remotely.
To learn more about these and other CHAUVET products visit us at www.chauvetlighting.com.
CH-222 User Manual
6
2005-07-22/17:40
APPENDIX
General Maintenance
To maintain optimum performance and minimize wear fixtures should be cleaned frequently. Usage
and environment are contributing factors in determining frequency. As a general rule, fixtures should
be cleaned at least twice a month. Dust build up reduces light output performance and can cause
overheating. This can lead to reduced lamp life and increased mechanical wear. Be sure to power off
fixture before conducting maintenance.
Unplug fixture from power. Use a vacuum or air compressor and a soft brush to remove dust
collected on external vents and internal components. Clean all glass when the fixture is cold with a
mild solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue. Apply
solution to the cloth or tissue and drag dirt and grime to the outside of the lens. Gently polish optical
surfaces until they are free of haze and lint. Do not to touch the lamp glass when cleaning fixture. Oil
and dirt can cause damage and premature aging of the lamp. In the event that the lamp is touched or
becomes dirty, clean the lamps with an alcohol wipe.
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to
optimize light output. Cleaning frequency depends on the environment in which the fixture operates:
damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit’s
optics. Clean with soft cloth using normal glass cleaning fluid. - Always dry the parts carefully. - Clean
the external optics at least every 20 days. Clean the internal optics at least every 30/60 days.
Returns Procedure
Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued.
Package must be clearly labeled with a Return Merchandise Authorization Number (RA #). Products
returned without an RA # will be refused. Call CHAUVET and request RA # prior to shipping the
fixture. Be prepared to provide the model number, serial number and a brief description of the cause
for the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate
packaging is the customer’s responsibility. CHAUVET reserves the right to use its own discretion to
repair or replace product(s). As a suggestion, proper UPS packing or double-boxing is always a safe
method to use.
Claims
Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be
reported to the carrier upon receipt of merchandise. It is the customer's responsibility to notify and
submit claims with the shipper in the event that a fixture is damaged due to shipping. Any other claim
for items such as missing component/part, damage not related to shipping, and concealed damage,
must be made within seven (7) days of receiving merchandise.
CH-222 User Manual
7
2005-07-22/17:40
Appendix
General Troubleshooting
Applies to
Foggers
& Snow
Dimmers
& Chaser
Symptom
Solution(s)
Lights
Controllers
Auto shut off
Check fan thermal switch reset
Beam is very dim or not Clean optical system or replace lamp
bright
Check 220/110v switch for proper setting
Breaker/Fuse keeps
blowing
Check total load placed on device
Chase is too slow
Check users manual for speed adjustment
Device has no power
Check for power on Mains.
Check device’s fuse. (internal and/or external)
Fixture is on but there
is no movement to the
audio
Make sure you have the correct audio mode on the control
switches. If audio provided via ¼” jack, make sure a live
audio signal exists
Adjust sound sensitivity knob
Fluid indicator not
working
The filter tip on the end of the tube inserted into the fluid
container must float freely in order to measure correctly,
check to see if perhaps it is stuck
Fogger or Snow output
has dropped
Clean with distilled water and vinegar
Replace hose
Lamps cuts off
sporadically
Possible bad lamp or fixture is overheating.
Lamp may be at end of its life.
Light will not come on
after power failure
Some discharge lamps require a cooling off period before
the electronics in the fixture can kick start it again, wait 5 to
10 minutes before powering up
Motor movements are
jerky or jumpy
Possible bad motor driver or sensors
Check polarity switch on controller
Moves slow
No flash
No fog
Check 220/110v switch for proper setting
Re-install bulb, may have shifted in shipping
Check fluid tank if empty
Make sure green light is on (for power)
No light output
Check slip ring & brushes for contact
Install bulb
Call service technician
Relay will not work
Check reset switch
Check cable connections
Remote does not work
Make sure connector is firmly connected to device
Check for damages possibly incurred during shipping
Unit wobbles when
rotating
CH-222 User Manual
8
2005-07-22/17:40
Appendix
Technical Specifications
WEIGHT & DIMENSIONS
Length.............................................................................................................................178 mm (7 in)
Width..........................................................................................................................159 mm (6.25 in)
Height .............................................................................................................................102 mm (4 in)
Weight.........................................................................................................................1.72 Kg (3.8 lbs)
POWER
Operating Range.........................................................................................120V 60 Hz or 230V 50 Hz
European Version ......................................................................................................230V/240V 50Hz
AC input.......................................................................................................... 3-prong IEC 60320 C14
LAMPS
EFP5..........................................................................................................................50 hr, 100W, 12v
THERMAL
Maximum ambient temperature......................................................................................... 40° (104° F)
FUSE
Main (115V AC)........................................................................................... 20mm Glass 2A Fast Blow
Main (230V AC)........................................................................................... 20mm Glass 1A Fast Blow
ORDERING INFORMATION
Abyss™ Jr................................................................................................................................ CH-222
Fuse 2A ........................................................................................................................ P170FUSE002
Fuse 1A ........................................................................................................................ P170FUSE001
Technical Support
Address:
Service Dept.
3000 N 29th Ct, Hollywood, FL 33020 (U.S.A.)
Support (Email):
Telephone:
Fax:
(954) 929-1115 - (Press 4)
(954) 929-5560 - (Attention: Service)
Website:
CH-222 User Manual
9
2005-07-22/17:40
|